Here are the items that we found.

Siemens 1PH81071MF220BA1
SIMOTICS M compact asynchronous motor 1500 r/min 14 kW 89 Nm 43.7 A 277 V 1750 r/min 15.5 kW 85 Nm 42 A 314 V 2000 r/min 18 kW 86 Nm 42.6 A 363 V 2200 r/min 19.8 kW 86 Nm 42.6 A 381 V water cooling degree of protection IP65 Incremental encoder SIN/COS 1 VPP 2048 S/R with C and...
Lead time
24h
Typical quote turnaround on in-stock items
Warranty
24 months
Coverage on eligible surplus and refurbished inventory
Inventory network
5M+
Parts across brands, PLCs, drives, sensors and motors
Request pricing for stock confirmation, condition and freight options
Trusted sellerGet a fast quote
Description
SIMOTICS M compact asynchronous motor 1500 r/min 14 kW 89 Nm 43.7 A 277 V 1750 r/min 15.5 kW 85 Nm 42 A 314 V 2000 r/min 18 kW 86 Nm 42.6 A 363 V 2200 r/min 19.8 kW 86 Nm 42.6 A 381 V water cooling degree of protection IP65 Incremental encoder SIN/COS 1 VPP 2048 S/R with C and D track (encoder IC2048S/R) with temperature sensor KTY 84-130 DESIGN IM B5 (IMV 1,IM V3) PLAIN SHAFT WITHOUT FITTED KEY; BEARING: STANDARD WITH FIXED BEARING, VIBRATION SEVERITY GRADE: R/A, SHAFT AND FLANGE ACCURACY: R TERMINAL BOX (ABOVE) CABLE ENTRY ON THE RIGHT SIGNAL CONNECTION D-END
Shipping & returns
Shipping & returns
We can ship via UPS, FedEx, and USPS. We can ship on customers' accounts as well. International delivery available via UPS and DHL. In stock items typically ship same day.
All products (new, refurbished, and repairs) are covered by the Industrial Automation Company's 2 Year Warranty. Manufacturer's Warranty does not apply.
Part number reference — 1PH8107-1MF22-0BA1
| Product family | SIMOTICS M 1PH8 Compact Asynchronous Motor |
| Series | SIMOTICS |
| Type | spindle motor |
Fault codes (937)
- Fault A01006 — Firmware update for DRIVE-CLiQ component required
- Fault A01007 — POWER ON for DRIVE-CLiQ component required
- Fault A01009 (N) — CU: Control module overtemperature
- Fault A01013 — CU: Fan operating time reached or exceeded
- Fault A01016 (F) — Firmware changed
- Fault A01017 — Component lists changed
- Fault A01020 — Writing to RAM disk unsuccessful
- Fault A01032 (F) — ACX: all parameters must be saved
- Fault A01035 (F) — ACX: Parameter back-up file corrupted
- Fault A01045 — CU: Configuring data invalid
All 937 fault codes with causes and remedies →
Full reference page for 1PH8107-1MF22-0BA1 →
Questions or need a quote? Call 877-727-8757 or email sales@iac.us.com.
Reliable Mission-Critical Support from a Certified Veteran-Owned Business
Verified stock, fast quotes, and expert support from a trusted veteran-owned business.