{"product_id":"omron-h3dk-hcl","title":"OMRON H3DK-HCL","description":"\u003cstyle\u003e\n            p { margin-bottom: 20px; }\n            h2, h3 { margin: 30px 0 15px; }\n            ul { margin-bottom: 20px; padding-left: 20px; }\n            li { margin-bottom: 10px; }\n        \u003c\/style\u003e\n        \u003ch2 style=\"margin: 30px 0 15px;\"\u003eOMRON H3DK-HCL AC100-120V - Power OFF-Delay Timer\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom: 20px;\"\u003eThe OMRON H3DK-HCL AC100-120V is a reliable solid-state Power OFF-delay timer designed for a range of industrial automation applications. This versatile device offers a time delay function that activates after the power supply is switched off, allowing for precise control over equipment shutdown sequences.\u003c\/p\u003e\n\n\u003ch3 style=\"margin: 30px 0 15px;\"\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eOperation Mode:\u003c\/strong\u003e Power OFF-delay, providing flexibility in managing post-power shutdown events.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eTime Range:\u003c\/strong\u003e Offers two time ranges, 1 to 12 seconds and 10 to 120 seconds, allowing for customizable delay settings to suit various applications.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eControl Output:\u003c\/strong\u003e Equipped with a single pole double throw (SPDT) relay output, ensuring compatibility with diverse control systems.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Compatible with 100 to 120 VAC power sources at frequencies of 50\/60 Hz.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eEnvironmental Durability:\u003c\/strong\u003e Operates within a wide temperature range of -20 to 55°C and humidity range of 25 to 85%, ensuring reliability in challenging environments.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eSafety and Protection:\u003c\/strong\u003e Features IP30 protection (terminal block IP20), ensuring resistance against dust and moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin: 30px 0 15px;\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003eRated Power Supply Voltage: 100 to 120 VAC, 50\/60 Hz\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003eAllowable Voltage Range: 85 to 110% of the rated voltage\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003ePower Consumption: Approximately 11.7 VA at 120 VAC\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003eRelay Life Expectancy: Minimum of 100,000 operations (electrical) and 10 million operations (mechanical)\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003eInsulation Resistance: Minimum of 100 MΩ at 500 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin: 30px 0 15px;\"\u003eUnique Selling Points:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eReliability and Precision:\u003c\/strong\u003e Offers high accuracy and stability in timing operations, with an operating time accuracy of ±1% full scale and setting error of ±10% full scale ±0.05 seconds.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eEnvironmental Adaptability:\u003c\/strong\u003e Designed to withstand vibration, shock, and static immunity, making it suitable for harsh industrial environments.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eEase of Installation:\u003c\/strong\u003e Uses terminal blocks for easy connection and setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin: 30px 0 15px;\"\u003eSafety and Compatibility:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003eThe device is designed to meet stringent safety standards, including impulse withstand voltage of up to 5 kV and dielectric strength of 2,000 VAC.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 20px;\"\u003eEnsure that the device is installed and operated in compliance with local safety regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin: 30px 0 15px;\"\u003eIdeal for Use in:\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e[Please insert specific applications or industries where the product is ideally used.]\u003c\/p\u003e","brand":"IAC Catalog","offers":[{"title":"Default Title","offer_id":41127283294292,"sku":"H3DK-HCL","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0575\/2986\/0180\/files\/default-1_12e44341-07e8-40d1-8c31-dc95eda6e6c4.webp?v=1777503149","url":"https:\/\/catalog.industrialautomationco.com\/products\/omron-h3dk-hcl","provider":"IAC Catalog","version":"1.0","type":"link"}